Gonano Shingle Saver
SHINGLE AGING RESISTANCE UNTREATED VS TREATED TEST
A new solution for extending and maintaining your roof. By using a nano-technology-driven approach, gonano developed a breathable, deep penetrating, clear, hydrophobic, and UV-resistant coating to make asphalt shingles more durable.
Gonano Shingle Saver is a deep penetrating technology that protects against water-soluble and freeze/thaw cycles.
Through constant development and the latest advances in nanotechnology, gonano developed the first nano-coating for asphalt shingles.
Once applied on the surface, the nanoparticles connect to the aggregate on the surface and the bitumen reating a hydrophobic environment.
The shielding reaction reduces the aging speed, increases its resistance to impact and wind.
Gonano’s nanoparticles have a longer service life and efficacity than traditional sealents.
FREE ESTIMATE
See if you can qualify now! Checking eligibility will not affect your credit score!
0% financing options are available to those who qualify!
TECHNOLOGY /ADVANTAGE
- Composition – Made with actives high-performance nanosize organosilane & organosiloxane. Its molecular structure with dual bonding properties allows stronger connections, thus increasing performance and resistance.
- Exceptional waterproofing – Penetrates deep within the shingle, chemically reacting within the pores and capillaries, creating a long-lasting hydrophobic surface that beads water.
- 100% breathable – Non-film forming. Allows moisture to escape without adverse effects to the sealer. Does not trap moisture.Made with actives high-performance nanosize organosilane & organosiloxane. Its molecular structure with dual bonding properties allows stronger connections, thus increasing performance and resistance.
- Improve adhesion between bitumen and aggregate – The chemical reaction increases the bonding between the substrate and aggregate by reacting with the aggregate and the bitumen.
- Improve oxidization resistance – Reduction of the creation of polar bonding that affect aging.
- Resist moisture intrusion – Resists wind-driven rain, spalling, pitting, and cracking.
- Resist organic growth – Mold, mildew lichen and efflorescence.
- Resist freeze-thaw & thermal cycling damage – Resists cracking by preventing the ingress of water.
- Provide ease of maintenance
- Improves durability – Prevents capillary uptake of water, UV degradation and oxidation process.
- Natural flat finish – Does not change surface appearance, UV stable, will not break down with light exposure.
- Can be applied to all shingle roofs – Ideal to be applied on roofs who are new or with low to no damages.
- Solvent based – Excellent for cold-weather environments.
- Incomparable 10-year warranty – Guaranteed to never delaminate, flake, chip, degrade from UV light exposure.
TYPICAL PROPERTIES
Appearance
Clear
Odor
Mild Petroleum Solvent
Packaging
4L, 20L and 200L drums
LOW VOC
250g/L maximum
Flash Point
>77°C
Relative Density
0.78 -0.81 g/cm3
Appearance
Clear
Odor
Mild Petroleum Solvent
Packaging
4L, 20L and 200L drums
LOW VOC
250g/L maximum
Flash Point
>77°C
Relative Density
0.78 -0.81 g/cm3
SURFACE PREPARATION
1. Clean
The asphalt substrate must be structurally sound and clean of oil, grease, dirt, wax, curing compounds, efflorescence, paints, previous sealers, adhesives and other contaminants that might interfere with the penetration of the sealer.
Power wash, acid etch or mechanically scarify as necessary to achieve the desired surface condition. Allow for proper dry time before application. May be applied to slightly damp surfaces, although maximum penetration is achieved on dry substrates. Do not apply if standing water is visible.
2. Installation temperature
Surface and air temperatures must be at least 33°F during application. Surface and air temperatures should not exceed 95°F. Do not apply when rain is expected within 12 hours following application. Do not apply during inclement weather or when inclement weather is expected within 12 hours.
3. Reparations
Crack, patching and expansion joint sealants can be applied before or after application; always test for compatibility and adhesion.
4. Protection
Protect people, property, vehicles, window glass, roofing materials, plastic products, shrubbery, landscaping and all surfaces not set for treatment from overspray.
APPLICATION
1. Do a test
Always test a small area before application to ensure desired performance, aesthetics, coverage rates and to verify application technique. Let test area dry thoroughly, 5-7 days, before inspection.
2. Stir
Always test a small area before application to ensure desired performance, aesthetics, coverage rates and to verify application technique. Let test area dry thoroughly, 5-7 days, before inspection.
3. How to apply
Apply with a roller, brush or low-pressure non-atomizing sprayer. Apply to saturation and roll or broom out any puddles until the sealer penetrates the substrate. If it starts to rain, stop treatment and cover the impregnated areas
3. Dry Time
Typical drying time is 4-6 hours at 25°C and 50%relative humidity. Cooler temperatures or higher relative humidity can extend the drying time.
Water repellency will continue to develop within 7
days of application.
4. Clean Up
Clean equipment, tools and surfaces with xylene. Unused or old material may be disposed of in a waste disposal site in accordance with your laws.
5. Precautions / Safety
Avoid contact with skin, eyes and clothing, do not take internally. Use appropriate safety equipment during application and handling.
BEST PERFORMANCE
- Proper application is the responsibility of the user.
- Proper application is the responsibility of the user.
- Will not inhibit water penetration through unsound or cracked surfaces with defective flashing, caulking or structural waterproofing.
- Spills should not be allowed to sit for extended periods of time, clean all spills in a timely manner.
- Take caution with specially coated glass.
- Test small areas before application to ensure the product does not discolor the coating.
- Plastic windows will turn opaque when sprayed with this product.
- Make sure the most current versions of technical data sheets are being used.
Coverage
1 coat: 50-70 S/F per L.
Variations in texture and porosity of substrate will affect the coverage and performance of the product.
Millions of nanoparticles
A formidable technology
- Adds 10 years of life
- Eco-friendly
- Money Saver
CALL NOW
